{"id":5181,"date":"2026-07-30T15:36:05","date_gmt":"2026-07-30T15:36:05","guid":{"rendered":"https:\/\/www.new-vision.net\/ultrasound-pacs\/"},"modified":"2026-07-30T15:36:05","modified_gmt":"2026-07-30T15:36:05","slug":"ultrasound-pacs","status":"publish","type":"page","link":"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/","title":{"rendered":"Ultrasound PACS with Automated Measurements and Report Templates"},"content":{"rendered":"<style>\n.nv-page{max-width:980px;margin:0 auto}\n.nv-page h1{margin:0 0 .5em}\n.nv-page h2{margin:1.8em 0 .6em}\n.nv-page h3{margin:1.3em 0 .3em;font-size:1.05em}\n.nv-lede{font-size:1.15em;line-height:1.65}\n.nv-page table{width:100%;border-collapse:collapse;margin:1.2em 0;font-size:.95em}\n.nv-page th,.nv-page td{border:1px solid #dde3ea;padding:.6em .8em;text-align:left;vertical-align:top}\n.nv-page th{background:#f4f7fa;font-weight:600}\n.nv-cta{background:#f4f7fa;border-left:4px solid #0a6ebd;padding:1em 1.2em;margin:1.6em 0}\n.nv-note{font-size:.9em;color:#5b6b7c}\n.nv-page ul,.nv-page ol{margin:.6em 0 1em 1.4em}\n<\/style>\n<div class=\"nv-page\">\n<h1>NewVision Ultrasound PACS<\/h1>\n<p class=\"nv-lede\">NewVision Ultrasound moves images, video and every measurement off the ultrasound machine automatically, then builds a complete professional report from a specialty template \u2014 obstetric, gynaecological, abdominal or cardiac. Measurements arrive through DICOM Structured Report with no dictation and no retyping, and the finished report and images go to your HIS, EMR or EHR.<\/p>\n<div class=\"nv-cta\">\n<p><strong>See it on your own machine.<\/strong> Tell us the ultrasound model and specialty and we will demonstrate measurement transfer and the matching report template. <a href=\"\/en\/contact-us\/\">Book an ultrasound demo<\/a> \u00b7 <a href=\"mailto:info@new-vision.net?subject=NewVision%20Ultrasound%20demo\">info@new-vision.net<\/a><\/p>\n<\/div>\n<h2>Where ultrasound workflow leaks time and accuracy<\/h2>\n<table>\n<tr>\n<th>Current practice<\/th>\n<th>What it costs<\/th>\n<th>With NewVision<\/th>\n<\/tr>\n<tr>\n<td>The clinician dictates measurements; an assistant types them<\/td>\n<td>Transcription errors, and most measurements never recorded at all<\/td>\n<td>Every measurement the device produces transfers with zero transcription error<\/td>\n<\/tr>\n<tr>\n<td>Patient details typed at the ultrasound keyboard<\/td>\n<td>Misspelled names, mismatched studies, duplicate records<\/td>\n<td>Demographics pushed to the device from the worklist<\/td>\n<\/tr>\n<tr>\n<td>The patient leaves with one small thermal printout<\/td>\n<td>No usable document for the referring physician; nothing to compare next visit against<\/td>\n<td>Complete report with images, measurement tables and reference graphs<\/td>\n<\/tr>\n<tr>\n<td>Images stay on the machine&#8217;s internal disk<\/td>\n<td>Overwritten when the disk fills or lost when the device is serviced \u2014 no evidence if a case is disputed<\/td>\n<td>Redundant archive; images retained as part of the medical record<\/td>\n<\/tr>\n<tr>\n<td>Reports exported by hand into the hospital system<\/td>\n<td>Manual paperwork, delays, and an incomplete e-health chain<\/td>\n<td>Automatic transfer to the HIS, EMR or EHR<\/td>\n<\/tr>\n<\/table>\n<p>Sites running this workflow report roughly a <strong>30% reduction in total examination and report preparation time<\/strong> \u2014 the gain comes from removing dictation and retyping, not from rushing the scan.<\/p>\n<h2>Two capabilities the rest of the system is built around<\/h2>\n<table>\n<tr>\n<th>Capability<\/th>\n<th>Why it is the deciding factor<\/th>\n<th>Detail<\/th>\n<\/tr>\n<tr>\n<td>Automated measurement transfer<\/td>\n<td>Data recorded by the machine reaches the report unchanged, including the measurements clinicians normally skip because typing them is not worth the time<\/td>\n<td><a href=\"\/en\/ultrasound-pacs\/automated-measurements\/\">How automated measurements work<\/a><\/td>\n<\/tr>\n<tr>\n<td>Professional report templates<\/td>\n<td>The document is the product the patient and the referring physician actually see, and the template decides whether it is complete<\/td>\n<td><a href=\"\/en\/ultrasound-pacs\/report-templates\/\">Ultrasound report templates<\/a><\/td>\n<\/tr>\n<\/table>\n<h2>Specialty modules<\/h2>\n<table>\n<tr>\n<th>Specialty<\/th>\n<th>Focus<\/th>\n<th>Page<\/th>\n<\/tr>\n<tr>\n<td>Obstetrics and perinatology<\/td>\n<td>Fetal biometry, growth against reference curves, Doppler, anomaly screening, serial comparison across visits<\/td>\n<td><a href=\"\/en\/services\/new-vision-ultrasound-obstetrics\/\">OB\/GYN ultrasound automation<\/a><\/td>\n<\/tr>\n<tr>\n<td>Gynaecology<\/td>\n<td>Uterus and adnexa, endometrium, follicle tracking, cyst characterisation<\/td>\n<td><a href=\"\/en\/ultrasound-pacs\/gynecology\/\">Gynaecology ultrasound reporting<\/a><\/td>\n<\/tr>\n<tr>\n<td>Abdominal and general radiology<\/td>\n<td>Organ-by-organ assessment with measured dimensions and comparison to normal ranges<\/td>\n<td><a href=\"\/en\/ultrasound-pacs\/abdominal\/\">Abdominal ultrasound reporting<\/a><\/td>\n<\/tr>\n<tr>\n<td>Cardiology<\/td>\n<td>Echocardiography: chamber dimensions, function, valves, Doppler haemodynamics<\/td>\n<td><a href=\"\/en\/ultrasound-pacs\/cardiology\/\">Echocardiography reporting<\/a><\/td>\n<\/tr>\n<\/table>\n<h2>Validated ultrasound systems<\/h2>\n<p>Measurement transfer depends on what the device emits, so validation is per manufacturer family rather than generic.<\/p>\n<table>\n<tr>\n<th>Manufacturer<\/th>\n<th>Series validated<\/th>\n<\/tr>\n<tr>\n<td>GE<\/td>\n<td>Voluson series<\/td>\n<\/tr>\n<tr>\n<td>Canon (Toshiba)<\/td>\n<td>Aplio series<\/td>\n<\/tr>\n<tr>\n<td>Hitachi<\/td>\n<td>Arietta series<\/td>\n<\/tr>\n<tr>\n<td>Philips<\/td>\n<td>OB\/GYN product series<\/td>\n<\/tr>\n<tr>\n<td>Samsung<\/td>\n<td>OB\/GYN product series<\/td>\n<\/tr>\n<\/table>\n<p class=\"nv-note\">A documented example: DICOM transfer was tested on a Toshiba ultrasound system at Akdeniz University Faculty of Medicine, Department of Obstetrics and Gynaecology, successfully transferring patient information, Structured Report data, images and video into NewVision. If your model is not listed, send us the make and software version and we will confirm what it emits.<\/p>\n<h2>Integration<\/h2>\n<table>\n<tr>\n<th>Interface<\/th>\n<th>What it does<\/th>\n<\/tr>\n<tr>\n<td>DICOM Modality Worklist<\/td>\n<td>Pushes appointment and patient data to the ultrasound device, removing keyboard entry at the machine<\/td>\n<\/tr>\n<tr>\n<td>DICOM Storage<\/td>\n<td>Receives images, video and Structured Report objects from the device<\/td>\n<\/tr>\n<tr>\n<td>HIS \/ HBYS, EMR and EHR<\/td>\n<td>Two-way exchange: worklist inbound, images and signed reports outbound. Turkish sites include HBYS integration and the e-Nab\u0131z chain<\/td>\n<\/tr>\n<tr>\n<td>Archive<\/td>\n<td>Automatic redundant archive and backup, retained as the institution&#8217;s policy requires<\/td>\n<\/tr>\n<tr>\n<td>Optional cloud<\/td>\n<td>Sharing with patients and referring physicians, telemedicine review, mobile and tablet access<\/td>\n<\/tr>\n<\/table>\n<h2>Track record<\/h2>\n<ul>\n<li>NewVision medical imaging software has been developed and supported continuously since 2003.<\/li>\n<li>URAL Telekom operates an ISO 13485:2016 medical device quality management system; the NewVision Fundus product on the same core is FDA cleared and CE marked.<\/li>\n<li>Ultrasound reference sites include Akdeniz University Hospital (Assoc. Prof. Dr. Cem Ya\u015far Sanhal), JNM Sa\u011fl\u0131k perinatology clinic (Prof. Dr. Murat Yayla) and VM Medical Park Kocaeli Hospital.<\/li>\n<li>The same <a href=\"\/en\/endoscopy-pacs\/dicom-integration\/\">DICOM engine<\/a> serves ultrasound, endoscopy and ophthalmic installations, so multi-department hospitals maintain one integration pattern.<\/li>\n<\/ul>\n<h2>Frequently asked questions<\/h2>\n<div class=\"nv-faq\">\n<h3>Do we need to replace our ultrasound machines?<\/h3>\n<p>No. NewVision works with the machines you own, provided they can send DICOM. The validated series list above covers the systems most commonly found in OB\/GYN, radiology and cardiology departments.<\/p>\n<h3>What if our device does not send Structured Reports?<\/h3>\n<p>Images and video still transfer, and measurements are entered or drawn on the images in NewVision instead. You lose the automatic population, not the reporting workflow \u2014 and many older machines can be enabled for SR output in their DICOM settings.<\/p>\n<h3>Is this a full PACS or only a reporting tool?<\/h3>\n<p>Both, depending on how you deploy it. It archives and retrieves studies like a departmental PACS, and it can also forward everything to an enterprise PACS while acting as the reporting layer.<\/p>\n<h3>Can patients receive their images?<\/h3>\n<p>Yes, through the optional cloud module \u2014 commonly used in obstetrics to share fetal images and video with parents, which is also the feature that drives word-of-mouth referral in private clinics.<\/p>\n<h3>How does it help if a case goes to court?<\/h3>\n<p>Because images and measurements are archived redundantly rather than left on the device, the visual record still exists years later. Hospitals that lose images have no evidence to rely on.<\/p>\n<h3>Can small clinics use it without a hospital information system?<\/h3>\n<p>Yes. An optional patient appointment module covers clinics that have no HIS, so the worklist still drives the workflow.<\/p>\n<\/div>\n<h2>Start with a demo on your specialty<\/h2>\n<div class=\"nv-cta\">\n<p><strong>NewVision \u2014 URAL Telekom<\/strong><br \/>\nR&amp;D Center: Akdeniz \u00dcniversitesi Antalya Teknokent, Ar-Ge 2 Ulu\u011fbey Apt, No: 3A \/ Z14, P\u0131narba\u015f\u0131 Mah. H\u00fcrriyet Cad., Konyaalt\u0131 \/ Antalya \/ T\u00fcrkiye<br \/>\nSales Office: 44 Tehama St, Suite 409, San Francisco, CA 94105, United States<br \/>\n<a href=\"tel:+905437222210\">+90 543 722 22 10<\/a> \u00b7 <a href=\"mailto:info@new-vision.net\">info@new-vision.net<\/a><\/p>\n<p><a href=\"\/en\/contact-us\/\">Request an ultrasound demo<\/a><\/p>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Organization\",\n      \"@id\": \"https:\/\/www.new-vision.net\/#organization\",\n      \"name\": \"NewVision\",\n      \"legalName\": \"URAL Telekom\",\n      \"url\": \"https:\/\/www.new-vision.net\/\",\n      \"logo\": \"https:\/\/www.new-vision.net\/wp-content\/uploads\/2021\/06\/logo.png\",\n      \"email\": \"info@new-vision.net\",\n      \"telephone\": \"+90-543-722-2210\",\n      \"foundingDate\": \"2003\",\n      \"description\": \"NewVision develops medical image management, PACS and structured reporting software for ultrasound, endoscopy and ophthalmic imaging, with DICOM and EMR\/EHR integration.\",\n      \"address\": [\n        {\n          \"@type\": \"PostalAddress\",\n          \"streetAddress\": \"Akdeniz \u00dcniversitesi Antalya Teknokent, Ar-Ge 2 Ulu\u011fbey Apt, No: 3A \/ Z14, P\u0131narba\u015f\u0131 Mah. H\u00fcrriyet Cad.\",\n          \"addressLocality\": \"Konyaalt\u0131\",\n          \"addressRegion\": \"Antalya\",\n          \"addressCountry\": \"TR\"\n        },\n        {\n          \"@type\": \"PostalAddress\",\n          \"streetAddress\": \"44 Tehama St, Suite 409\",\n          \"addressLocality\": \"San Francisco\",\n          \"addressRegion\": \"CA\",\n          \"postalCode\": \"94105\",\n          \"addressCountry\": \"US\"\n        }\n      ],\n      \"sameAs\": [\n        \"https:\/\/www.facebook.com\/newvision.ultrasound\",\n        \"https:\/\/www.instagram.com\/new_vision_ultrasound\"\n      ]\n    },\n    {\n      \"@type\": \"WebPage\",\n      \"@id\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/#webpage\",\n      \"url\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/\",\n      \"name\": \"Ultrasound PACS and Reporting Software with Automated Measurements\",\n      \"inLanguage\": \"en\",\n      \"about\": { \"@id\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/#software\" },\n      \"publisher\": { \"@id\": \"https:\/\/www.new-vision.net\/#organization\" }\n    },\n    {\n      \"@type\": \"SoftwareApplication\",\n      \"@id\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/#software\",\n      \"name\": \"NewVision Ultrasound\",\n      \"applicationCategory\": \"HealthApplication\",\n      \"applicationSubCategory\": \"Ultrasound PACS, automated measurement transfer and structured reporting\",\n      \"operatingSystem\": \"Windows\",\n      \"url\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/\",\n      \"description\": \"Ultrasound image management and reporting software with automated measurement transfer over DICOM Structured Report, professional specialty report templates, redundant archive and EMR\/EHR integration for obstetrics, gynaecology, abdominal and cardiac ultrasound.\",\n      \"featureList\": [\n        \"Automated measurement transfer via DICOM Structured Report\",\n        \"Professional report templates with reference graphs\",\n        \"DICOM Modality Worklist push to the ultrasound device\",\n        \"Image and video archive with redundant backup\",\n        \"EMR, EHR and HIS integration\",\n        \"Serial comparison against previous examinations\",\n        \"Optional cloud sharing and telemedicine\"\n      ],\n      \"audience\": {\n        \"@type\": \"MedicalAudience\",\n        \"audienceType\": \"Obstetrics, gynaecology, radiology and cardiology ultrasound departments and clinics\"\n      },\n      \"publisher\": { \"@id\": \"https:\/\/www.new-vision.net\/#organization\" },\n      \"offers\": { \"@type\": \"Offer\", \"availability\": \"https:\/\/schema.org\/InStock\", \"url\": \"https:\/\/www.new-vision.net\/en\/contact-us\/\" }\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"@id\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/#breadcrumb\",\n      \"itemListElement\": [\n        { \"@type\": \"ListItem\", \"position\": 1, \"name\": \"NewVision\", \"item\": \"https:\/\/www.new-vision.net\/en\/\" },\n        { \"@type\": \"ListItem\", \"position\": 2, \"name\": \"Ultrasound PACS\", \"item\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/\" }\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"@id\": \"https:\/\/www.new-vision.net\/en\/ultrasound-pacs\/#faq\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Do we need to replace our ultrasound machines?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"No. NewVision works with existing machines provided they can send DICOM. Validated series include GE Voluson, Canon (Toshiba) Aplio, Hitachi Arietta, and Philips and Samsung OB\/GYN series.\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What if the ultrasound device does not send DICOM Structured Reports?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Images and video still transfer, and measurements are entered or drawn on the images in NewVision instead. Many older machines can also be enabled for SR output in their DICOM settings.\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is NewVision Ultrasound a full PACS or only a reporting tool?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Both, depending on deployment. It archives and retrieves studies like a departmental PACS, and it can forward everything to an enterprise PACS while acting as the reporting layer.\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can patients receive their ultrasound images?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes, through the optional cloud module, commonly used in obstetrics to share fetal images and video with parents.\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How does the archive help in a malpractice claim?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Because images and measurements are archived redundantly rather than left on the device, the visual record still exists years later and can be used as evidence.\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can small clinics use it without a hospital information system?\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes. An optional patient appointment module covers clinics with no HIS, so a worklist still drives the workflow.\" }\n        }\n      ]\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ultrasound image management and reporting software: automated measurement transfer over DICOM Structured Report, professional specialty templates, redundant archive and EMR\/EHR integration.<\/p>\n","protected":false},"author":12,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/pages\/5181"}],"collection":[{"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/comments?post=5181"}],"version-history":[{"count":0,"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/pages\/5181\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.new-vision.net\/en\/wp-json\/wp\/v2\/media?parent=5181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}